TitleProduct

6ES7314-1AF10-0AB0

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Zhejiang

  • Validity to:

    Long-term effective

  • Last update:

    2020-10-09 18:04

  • Browse the number:

    453

Send an inquiries

Company Profile

Taizhou Xinkong Automation Technology Co., Ltd

By certification [File Integrity]

Contact:andingan(Mr.)  

Email:

Telephone:

Phone:

Area:Zhejiang

Address:Zhejiang

Website:http://www.plcchinasupplier.com/ http://andingan.hengxumjjx.com/

Product Details


Technical data


SIMATIC S7-300, CPU 314 CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 48 KBYTE WORKING MEMORY MICRO MEMORY CARD NECESSARY

General information

HW functional status

01

Firmware version

V2.0.0

Engineering with

● Programming package

STEP 7 V5.1 SP4 or higher

Supply voltage

Rated value (DC)


● 24 V DC

Yes

permissible range, lower limit (DC)

20.4 V

permissible range, upper limit (DC)

28.8 V

external protection for power supply lines (recommendation)

2 A min.

Input current

Current consumption (rated value)

600 mA

Current consumption (in no-load operation), typ.

60 mA

Inrush current, typ.

2.5 A

I²t

0.5 A²·s

Power loss

Power loss, typ.

2.5 W

Memory

Work memory

● integrated

48 kbyte

● expandable

No

Load memory

● Plug-in (MMC)

Yes

● Plug-in (MMC), max.

8 Mbyte

● Data management on MMC (after last programming), min.

10 y

Backup

● present

Yes; Guaranteed by MMC (maintenance-free)

Battery

Backup battery

● Backup time, max.

1 008 h; At 40 °C ambient temperature

CPU processing times

for bit operations, typ.

0.1 µs

for bit operations, max.

0.2 µs

for word operations, typ.

0.2 µs

for fixed point arithmetic, typ.

2 µs

for floating point arithmetic, typ.

3 µs

CPU-blocks

Number of blocks (total)

1 024; (DBs, FCs, FBs OBs, SDBs); the maximum number of loadable blocks can be reduced by the MMC being used.

DB

● Number, max.

511; DB 0 reserved

● Size, max.

16 kbyte

FB

● Number, max.

512; From FB 0 to FB 511

● Size, max.

16 kbyte

FC

● Number, max.

512; from FC 0 to FC 511

● Size, max.

16 kbyte

OB

● Number, max.

see instruction list

● Size, max.

16 kbyte

Nesting depth

● per priority class

8

● additional within an error OB

4

Counters, timers and their retentivity

S7 counter

● Number

256

Retentivity

— adjustable

Yes

— preset

Z 0 to Z 7

Counting range

— adjustable

Yes

— lower limit

0

— upper limit

999

IEC counter

● present

Yes

● Type

SFB

● Number

Unlimited (limited only by RAM capacity)

S7 times

● Number

256

Retentivity

— adjustable

Yes

— preset

No retentivity

Time range

— lower limit

10 ms

— upper limit

9 990 s

IEC timer

● present

Yes

● Type

SFB

● Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

retentive data area in total

all (incl. memory bits, times, counters)

Flag

● Number, max.

256 byte

● Retentivity preset

MB 0 to MB 15

● Number of clock memories

8; 1 memory byte

Address area

I/O address area

● Inputs

1 kbyte

● Outputs

1 kbyte

Process image

● Inputs

128 byte

● Outputs

128 byte

Digital channels

● Inputs

1 024

— of which central

1 024

● Outputs

1 024

— of which central

1 024

Analog channels

● Inputs

256

— of which central

256

● Outputs

256

— of which central

256

Hardware configuration

Number of DP masters

● integrated

0

● via CP

4

Number of operable FMs and CPs (recommended)

● FM

8

● CP, PtP

8

● CP, LAN

10

Rack

● Racks, max.

4

● Modules per rack, max.

8

Time of day

Clock

● Hardware clock (real-time)

Yes

● retentive and synchronizable

Yes

● Backup time

6 wk; At 40 °C ambient temperature

● Deviation per day, max.

10 s

Operating hours counter

● Number

1

● Number/Number range

0

● Range of values

0 to 2^31 hours (when using SFC 101)

● Granularity

1 h

● retentive

Yes; Must be restarted at each restart

Clock synchronization

● supported

Yes

● to MPI, master

Yes

● to MPI, slave

Yes

● in AS, master

Yes

Analog inputs

integrated channels (AI)

0

Analog outputs

integrated channels (AO)

0

1. Interface

Interface type

Integrated RS 485 interface

Physics

RS 485

Isolated

No

Power supply to interface (15 to 30 V DC), max.

200 mA

Protocols

● MPI

Yes

● PROFIBUS DP master

No

● PROFIBUS DP slave

No

● Point-to-point connection

No

MPI

● Number of connections

12

● Transmission rate, max.

187.5 kbit/s

Services

— PG/OP communication

Yes

— Routing

No

— Global data communication

Yes

— S7 basic communication

Yes

— S7 communication

Yes

— S7 communication, as client

No; but via CP and loadable FB

— S7 communication, as server

Yes

Communication functions

PG/OP communication

Yes

Global data communication

● supported

Yes

● Number of GD loops, max.

4

● Number of GD packets, max.

4

● Number of GD packets, transmitter, max.

4

● Number of GD packets, receiver, max.

4

● Size of GD packets, max.

22 byte

● Size of GD packet (of which consistent), max.

22 byte

S7 basic communication

● supported

Yes

● User data per job, max.

76 byte

● User data per job (of which consistent), max.

76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)

S7 communication

● supported

Yes

● as server

Yes

● as client

Yes; Via CP and loadable FB

● User data per job, max.

180 byte; With PUT/GET

● User data per job (of which consistent), max.

64 byte

S5 compatible communication

● supported

Yes; via CP and loadable FC

Number of connections

● overall

12

● usable for PG communication

11

— reserved for PG communication

1

— adjustable for PG communication, min.

1

— adjustable for PG communication, max.

11

● usable for OP communication

11

— reserved for OP communication

1

— adjustable for OP communication, min.

1

— adjustable for OP communication, max.

11

● usable for S7 basic communication

8

— reserved for S7 basic communication

8

— adjustable for S7 basic communication, min.

0

— adjustable for S7 basic communication, max.

8

S7 message functions

Number of login stations for message functions, max.

12; Depending on the configured connections for PG/OP and S7 basic communication

Process diagnostic messages

Yes

simultaneously active Alarm-S blocks, max.

40

Test commissioning functions

Status block

Yes

Single step

Yes

Number of breakpoints

2

Status/control

● Status/control variable

Yes

● Variables

Inputs, outputs, memory bits, DB, times, counters

● Number of variables, max.

30

— of which status variables, max.

30

— of which control variables, max.

14

Forcing

● Forcing

Yes

● Forcing, variables

Inputs, outputs

● Number of variables, max.

10

Diagnostic buffer

● present

Yes

● Number of entries, max.

100

— adjustable

No

Configuration

Configuration software

● STEP 7

Yes; V5.1 SP4 and higher

Programming

● Command set

see instruction list

● Nesting levels

8

● System functions (SFC)

see instruction list

● System function blocks (SFB)

see instruction list

Programming language

— LAD

Yes

— FBD

Yes

— STL

Yes

— SCL

Yes

— CFC

Yes

— GRAPH

Yes

— HiGraph®

Yes

Know-how protection

● User program protection/password protection

Yes

Dimensions

Width

40 mm

Height

125 mm

Depth

130 mm

Weights

Weight, approx.

280 g

last modified: